x
Send Your Inquiry Today
Quick Quote

Fiberglass Fire Blanket, Fire Blanket ht800, Fiberglass Welding Blanket

A ceramic insulation blanket, also sold as a ceramic fiber blanket, is a needle-punched aluminosilicate fiber blanket used to insulate fixed equipment that runs hot. Its main applications are furnace lining, kiln insulation, process heaters, steam piping, boilers, ladle and tundish covers, and passive fire protection.

This guide goes application by application. For each one, it explains why a ceramic blanket fits and how to choose the grade, density and thickness for your project.

Why Ceramic Fiber Works at High Temperatures

Why Ceramic Fiber Works at High Temperatures
Why Ceramic Fiber Works at High Temperatures

The blanket works because of its structure. Fine fibers trap millions of small air pockets, which gives it very low thermal conductivity and makes it lightweight and flexible. That combination matters for three reasons.

  • Heat stays inside the equipment. Low conductivity means less heat reaches the shell.
  • The lining stores very little heat. A light lining takes less energy to heat and releases less when it cools, which suits equipment that cycles on and off.
  • It follows the equipment shape. Flexibility lets it follow complex geometry and irregular surfaces, so it leaves fewer gaps than rigid materials.

The effect on heat retention has been measured. A university study of four reheating furnaces in discontinuous operation found that placing low thermal mass ceramic fiber at the hot face reduced wall storage loss by about 10-85% and wall heat loss by about 15-60%. Results depend on the furnace and its duty cycle, so treat the range as an indication, not a promise for your equipment. It does explain why this is the standard high temperature insulation choice for batch and cyclic heating.

Two further properties come from the supplier’s data. The blanket is chemically inert to most corrosive agents, furnace atmospheres and molten non-ferrous metals. Its properties are also restored after drying if it is exposed to steam or water. Chemical inertness means the fibers resist attack. It does not make the blanket a shield against direct metal splash, which is covered in the steel section below.

Temperature Grades at a Glance

Temperature Grades at a Glance
Temperature Grades at a Glance
GradeMax TemperatureContinuous TemperatureBest Fit
STD1,100°C950°CLow to medium temperature equipment, pipes, linings
HP1,260°C1,100°CMost common grade, heat treatment furnaces, kilns
HZ1,360°C1,200°CDemanding applications needing higher purity
ZR1,430°C1,350°CSevere, fluctuating temperatures and thermal shock

Always size against the continuous column and keep a margin. The maximum is a short-term limit.

The grades differ because of chemistry. Impurities such as iron oxide and titania act as fluxes that lower the melting point, so higher grades remove them. The top grades add zirconia, which acts as a crystal stabilizer and limits shrinkage and degradation at extreme temperatures. Paying for ZR when HP runs well inside its limit adds cost with no benefit.

Applications and Why a Ceramic Blanket Fits

Applications and Why a Ceramic Blanket Fits
Applications and Why a Ceramic Blanket Fits

Furnaces and Kilns

The blanket is used as a hot-face lining in intermittent and continuous furnaces, as backup insulation behind brick or castable, as flexible seals and gaskets on furnace doors, and for wrapping high-temperature components. The reason it fits is low heat storage. In batch operations such as shuttle kilns, a light furnace lining heats and cools faster, which raises productivity.

For most heat treatment furnaces and kiln insulation, HP is the usual starting point. It is the grade the supplier lists as most common, with a continuous rating of 1,100°C. Choose it if your process stays comfortably inside that figure. Move to HZ or ZR only when continuous temperature or thermal shock demands it.

Real-world example: the Timpuri Noi plant in Bucharest modernized a heat treatment furnace by replacing its conventional molded refractory lining with ceramic fiber. A paper by N. Angelescu compares measurements taken before and after the change and reports fuel savings of up to about 40% against furnaces with traditional linings. The figure comes from one furnace and its duty cycle, so read it as a sign of what low heat storage can do in a batch heat treatment furnace, not as a target for yours. When you brief a supplier, give the firing curve, the atmosphere and how often the doors are opened, because those decide how much of that saving you can expect.

Petrochemical Heaters and Piping

Ceramic blanket is used as primary insulation in process heaters, reformers and ethylene cracking furnaces, where efficiency drives operating cost in continuous, high-volume running. It also insulates high-temperature piping for personnel protection, and it is wrapped around vessel skirts and structural supports as part of passive fire protection systems.

For lower-temperature piping, STD may be enough, because its role is to hold surface temperature down, not to survive extreme heat. Heater walls running hotter need a higher grade. In both cases, set thickness from a cold-face calculation, so personnel protection is a number you can verify.

Real-world example: a case study presented at the 2024 AIChE Spring Meeting describes the convection sections of a Petrobras atmospheric heater (REPLAN, 2010) and a reformer furnace (RPBC, 2023). The conventional lining there was castable, insulating firebrick or anchored ceramic fiber, and replacing it usually meant removing piping to reach the wall. The project used custom vacuum-formed ceramic fiber shapes installed from the outside of the furnace, which avoided removing the piping and cut downtime. A separate case study of the Valero Benicia refinery’s steam methane reformers, whose radiant sections are lined with ceramic fiber, points to a second condition worth planning for: unprotected ceramic fiber at the hot face can deteriorate over time as surface fibers crystallize and become friable, which then fouls the convection section. Both were written with supplier or contractor involvement, so treat them as case reports. For your own project, ask how the lining will be installed and accessed, and ask the supplier about hot-face condition and expected service life at your temperature.

Power Generation

Typical uses are boiler insulation, high-pressure steam piping, Heat Recovery Steam Generator ductwork, and removable insulation pads for turbines and valves. The reasoning is heat loss. Over long steam runs, minimal loss helps maintain steam quality and pressure. Removable pads also give maintenance crews access, and they add acoustic insulation.

Ductwork carries moving gas, so density matters here. A denser blanket is stronger, more resilient to compression and more resistant to erosion from high-velocity gases. For static piping, density can be lower, as long as the thermal calculation supports it.

Real-world example: at the 385-MW Watson Cogeneration plant, HRSG insulation was wearing out in about four years, well short of the 10 years or more normally expected, in ductwork carrying gas turbine exhaust at velocities of up to about 120 ft/s. The original design was ceramic fiber blanket on studs covered by a 14-gauge stainless steel shroud. According to a supplier article, the plant moved to weld-on ceramic fiber modules made with a fiber that hardens after an organic lubricant burns out, which could be installed without the shroud, and it had retrofitted its fourth HRSG at the time of writing. This is the airflow and erosion case in practice: gas velocity, not temperature alone, decided the specification. For removable pads, a published supplier specification for gas turbine exhaust blankets uses a 128 kg/m³ ceramic needled fiber mat as the hot layer, a fiberglass layer on the outside and integral fasteners, which shows how pads that are handled at every service are built differently from static insulation.

Steel and Metallurgy

The steel industry uses ceramic blanket to line reheat furnace doors and roofs, and as insulation for ladle lids, tundish covers and soaking pit covers. The purpose is to prevent premature solidification of molten metal and to hold the temperature control that protects metal quality. It also reduces the radiant heat that reaches the equipment behind it.

It is important to separate two different jobs here. Thermal insulation slows heat moving through a wall or cover, and that is what ceramic blanket is specified to do. Protection from direct metal splash is a different job, because the surface has to shed molten droplets and resist abrasion. For direct splash or heavy slag, vermiculite coated fiberglass or silica are the products designed for it. If the job is a movable spark or splash shield during hot work, not fixed insulation, a fiberglass welding blanket is the better tool. A needled insulation blanket is installed in place, while a welding blanket is designed to be hung, moved and reused.

Real-world example: since 2016, Usiminas has replaced the alumina-silica refractory lining of its slab reheating furnaces in Ipatinga, Brazil, with refractory ceramic fiber blocks, which are the same fiber family as a blanket. A paper at the 2022 ABM congress reports reduced heat loss through the furnace walls, energy gains, a better preserved steel shell and higher furnace availability, and it includes a post-mortem analysis of how the fiber behaved at industrial scale. A reheating furnace heats solid slabs, so this is purely an insulation job. Equipment near a pouring area that could be hit by droplets needs a splash-rated cover as well, and the ceramic insulation should not be counted on to do that job.

Passive Fire Protection

Passive Fire Protection
Passive Fire Protection

The blanket serves as an insulating core in fire-rated doors, marine bulkheads, expansion joints and chimney systems. Its non-combustible nature and very low thermal conductivity slow heat transfer, which prevents ignition on the unexposed side and helps equipment reach a fire endurance rating such as 1 hour or 2 hours.

Remember that a fire rating belongs to the tested assembly, not the blanket alone. Ask the supplier which assembly and test the data refers to before you rely on it.

Real-world example: high-temperature fiber blanket systems for structural steel are sold with the test and fire exposure they were approved for. One major manufacturer lists its structural steel blanket system as tested to EN 13381-4 under both cellulosic and hydrocarbon fire exposure, with Lloyd’s Register type approval for the hydrocarbon system. The same page explains that steel is traditionally kept below 550°C, where it retains 60% of its room temperature strength, and that critical temperatures of 400°C to 620°C are specified depending on load, with 400°C widely used offshore. For a buyer, the rating belongs to the tested system, so ask which exposure, which steel temperature and which fixing method the data was tested with, and share your required rating and critical temperature with the supplier before relying on any figure.

When A Ceramic Blanket Is Not The Right Choice

Not every hot-environment job needs one. For hand-deployed protection against small fires, a fiberglass fire blanket is rated 550°C continuous and is designed for pull-tab deployment. For flexible wraps and hot work where abrasion matters, the Fire Blanket HT800 uses a dense 8-harness satin weave at about 800-880 g/m² and is also rated 550°C continuous. For direct molten metal splash, vermiculite coated fiberglass or silica are the options built to shed droplets.

The reason is function. Fiberglass is a textile that can be dragged, folded and reused, while a ceramic blanket is a fixed insulation layer. Using the wrong one wastes money in one direction and risks failure in the other.

How To Choose The Right Specification For Your Project

How To Choose The Right Specification For Your Project
How To Choose The Right Specification For Your Project

Work through these steps in order, and write the answers into your purchase specification.

  1. Define the continuous and peak temperature. Match the continuous figure to the grade’s continuous column, with a margin. This is the reason to avoid sizing by the maximum, which is a short-term limit.
  2. Define the atmosphere and gas flow. The blanket is inert to most corrosive agents, but fast gas needs density. High-velocity flow erodes low-density material first.
  3. Set the cold-face target. Decide what shell temperature you need for safety and efficiency. This sets thickness, and thermal resistance scales with it, so doubling thickness of a given grade and density roughly doubles insulating capability, according to the supplier. Layering is also possible.
  4. Consider your duty cycle. Frequent heating and cooling favors a light lining, because low heat storage saves energy each cycle. Continuous running makes conductivity the bigger factor.
  5. Check mechanical conditions. Compression, vibration and access panels push you toward higher density or custom shapes.
  6. Decide on fit. Precise cutting avoids hot spots and thermal bridges. Specify die-cut parts for doors, covers and removable pads, not site-cut offcuts.
ApplicationStart WithWhy
Heat treatment furnace or kilnHPMost common grade, 1,100°C continuous
Low to medium temperature pipes and liningsSTDCost matches the duty
Steam piping and boilersSTD or HP by surface temperatureHeat retention depends on thickness more than grade
HRSG ductworkHigher densityResists erosion from fast gas
Fluctuating high temperature, thermal shockZRZirconia limits shrinkage

Treat the table as a starting point. These recommendations hold when conditions are ordinary for that application, and they change when any of the following change:

  • Operating temperature: HP suits heat treatment furnaces and kilns only while the continuous temperature stays comfortably inside 1,100°C. As the continuous figure approaches a grade’s rating, step up a grade or reduce the exposure rather than relying on the maximum.
  • Atmosphere: the blanket is inert to most corrosive agents and furnace atmospheres, but if your atmosphere is unusual, confirm it with the supplier before ordering.
  • Thermal cycling: ordinary cycling inside HP’s range is handled by the low heat storage of the lining. Severe or rapid temperature swings are where ZR is intended, since zirconia limits shrinkage.
  • Airflow: static insulation can often use a lower density. Moving gas, as in HRSG ductwork, needs a higher density because high-velocity flow erodes low-density material first.
  • Mechanical wear: compression, vibration and frequent removal push the specification toward higher density and custom die-cut parts.

The supplier offers complimentary thermal calculations based on furnace temperature and wall thickness, so confirm the final grade, density and thickness that way.

Handling, Health and Safety Planning

Refractory ceramic fibers need a handling plan. IARC has classified them as possibly carcinogenic to humans (Group 2B), so plan for dust control, suitable respiratory protection and the supplier’s safety data sheet before the material arrives. Also plan how old lining will be removed at end of life. This is a standard industrial procedure, not a reason to avoid the product, but it belongs in the purchase specification.

What To Ask A Supplier Before You Order

Ask for:

  • The grade, with continuous and maximum temperature shown separately
  • Density and thickness, with tolerances
  • A batch test report listing linear shrinkage and thermal conductivity
  • The safety data sheet
  • Custom cutting or die-cutting options, plus packaging for transport
  • A prototype for complex shapes

ZS Fiberglass states that its ceramic fiber blanket ships with batch-specific reports, that it offers thermal calculations before purchase, and that custom parts are made through slitting, laminating and CNC die-cutting, with a prototype for approval before full production. Confirm each item against your own order.

FAQs

What Grade of Ceramic Insulation Blanket Do I Need? 

Choose by continuous operating temperature, not the maximum. STD is rated 950°C continuous, HP 1,100°C, HZ 1,200°C and ZR 1,350°C. Leave a margin, and step up only if your process requires it.

Can It Replace Brick in a Furnace? 

The supplier lists it as a primary hot-face lining and as backup insulation behind brick or castable. Whether it can replace brick depends on gas velocity, mechanical load and temperature, so confirm with the supplier’s calculation.

Can a Ceramic Blanket Protect Against Molten Metal Splash? 

Not as its main job. It is specified to insulate, and it reduces radiant heat reaching equipment behind it. Where a surface can be hit directly by molten metal or heavy slag, use a product designed to shed droplets, such as vermiculite coated fiberglass or silica, and keep the ceramic blanket for the insulation layer.

What Should I Send the Supplier for a Thermal Calculation? 

Send the furnace or process temperature, the wall or cover construction and thickness, the shell temperature you want, how often the equipment heats and cools, the atmosphere, any gas flow across the lining, and any mechanical load or frequent removal. The more of these you provide, the less the supplier has to assume.

Two Quotes Show the Same Grade but Different Densities. Which Should I Choose? 

The grade tells you the temperature rating, while density changes conductivity and mechanical strength. Higher density generally lowers conductivity and resists compression and gas erosion, but a lower density may be enough where gas velocity and mechanical load are low. Ask for the batch test report showing thermal conductivity and shrinkage for each, and decide from the thermal calculation, not price alone.

How Should I Specify a Blanket for Equipment That Heats and Cools Several Times a Day? 

Low heat storage is the main benefit, because a light lining uses less energy each cycle. If the swings stay inside the continuous rating of the grade, a standard choice such as HP can be considered. If they are severe and fast, discuss ZR with the supplier, since zirconia limits shrinkage. Give the supplier the temperature range and the cycles per day.

 

Update cookies preferences
Scroll to Top